Trentec,
Inc.
Environmental
Qualification
Electronic
Equipment Testing Capabilities
EMI
Testing
Firmware
Verification
Harsh Environmental
Testing
Material
Identification: Infrared spectrometer
Material
Database: Material aging & radiation
effects
library
Radiation
Aging: Typically up to 10E8 Rads. Using
Cobalt 60
Thermal
Aging: 8 Ovens (4’x 4’x 4’ up to 650°F
/ 343°C)
Humidity
Testing: 1 Humidity chamber (2’ x 2’
x 2’)
(-20°
to 500°F / 230°C up to 100% RH)
LOCA
/ HELB: 4 Accident chambers with spray
& submergence capability ( > 400°F / 200°C & 100 PSI)
Power:
120V / 1f
/ 60 Hz up to 500A AC
240V / 3f
/ 60 Hz up to 100A AC
480V / 3f
/ 60 Hz up to 600A AC
600V / 1f/
60 Hz up to 500A AC
0-120V / 1f
/ 60 Hz up to 30A AC
0-480V / 3f
/ 60 Hz up to 30A AC
0-700A AC @ 12V
0-1400A AC @ 6V
0-250V up to 350A DC
Pneumatics:
0-120 PSIG shop air
0-3300
PSIG Bottled air
0-2500
PSIG Bottled nitrogen
0-600
CFM
Hydraulics:
0-10,000 PSIG static
Water:
0-100 PSIG at 10 GPM shop water
Testing
Standards Utilized: IEEE 323-1974/1983
10
CFR 50.49
Mild Environmental
Analysis
Mild
Analysis: Material aging & radiation effects library used
to evaluate the expected life of components installed in a mild environment.
Temperature:
0 - 50°C (60°C for some components) Humidity:
40 - 95% RH non condensing
Radiation:
10E3 Rads for electronics
10E4 Rads for most electromechanical
devices
10E6 Rads for phenolic components
Testing
Standards Utilized: IEEE 323-1974/1983
|
Trentec
Home
Equipment
Qualification And Dedication Services
Seismic
Qualification
Environmental
Qualification
Dedication
Services
EPRI/SQURTS
Program
Contact
Us
Site
Map
Trentec, Inc.
4600 East
Tech Drive
Cincinnati,
Ohio 45245 U.S.A.
Ph 513-528-7900
Fax 513-528-9292
Email
|