Trentec, Inc.
Environmental Qualification

Electronic Equipment Testing Capabilities

EMI Testing
Firmware Verification

Harsh Environmental Testing

Material Identification: Infrared spectrometer
Material Database:  Material aging & radiation 
effects library
Radiation Aging:  Typically up to 10E8 Rads. Using Cobalt 60
Thermal Aging:  8 Ovens (4’x 4’x 4’ up to 650°F / 343°C)
Humidity Testing:  1 Humidity chamber (2’ x 2’ x 2’)
(-20° to 500°F / 230°C up to 100% RH)
LOCA / HELB:  4 Accident chambers with spray & submergence capability ( > 400°F / 200°C & 100 PSI)
LOCA
Power:
120V / 1f / 60 Hz up to 500A AC
240V / 3f / 60 Hz up to 100A AC
480V / 3f / 60 Hz up to 600A AC
600V / 1f/ 60 Hz up to 500A AC
0-120V / 1f / 60 Hz up to 30A AC
0-480V / 3f / 60 Hz up to 30A AC
0-700A AC @ 12V
0-1400A AC @ 6V
0-250V up to 350A DC
Pneumatics:
0-120 PSIG shop air
0-3300 PSIG Bottled air
0-2500 PSIG Bottled nitrogen
0-600 CFM
Hydraulics:  0-10,000 PSIG static
Water:   0-100 PSIG at 10 GPM shop water
Testing Standards Utilized: IEEE 323-1974/1983
10 CFR 50.49


Mild Environmental Analysis

Mild Analysis:  Material aging & radiation effects library used to evaluate the expected life of components installed in a mild environment. 
Temperature:  0 - 50°C (60°C for some components) Humidity: 40 - 95% RH non condensing 
Radiation: 10E3 Rads for electronics 
10E4 Rads for most electromechanical devices 
10E6 Rads for phenolic components
Testing Standards Utilized: IEEE 323-1974/1983


Trentec Home

Equipment Qualification And Dedication Services

Seismic Qualification

Environmental Qualification

Dedication Services

EPRI/SQURTS Program

Contact Us

Site Map


Trentec, Inc.
4600 East Tech Drive
Cincinnati, Ohio 45245 U.S.A.
Ph 513-528-7900
Fax 513-528-9292
Email